DATA CENTER EQUIPMENT • VENDOR-INDEPENDENT SOURCING • SYSTEM INTEGRATION
Vendor-independent sourcing and integration of data center equipment
Power, cooling, rack, cabling, physical security and fire detection equipment, from sizing to handover on site

The equipment we supply
Low- and medium-voltage incoming supply, transformers, main and sub-distribution boards, uninterruptible power supplies (UPS), UPS battery banks, diesel gensets, automatic and static transfer switches (ATS/STS), rack-level power distribution (PDU, rPDU), metering and monitoring.
Precision cooling units (CRAC/CRAH), chillers, in-row and in-rack cooling, direct liquid cooling (DLC), free cooling, heat exchangers, hot and cold aisle containment, temperature and humidity sensors.
19" rack cabinets and frames, containment components, cable managers, blanking panels, rack-level monitoring, plinths and fixings.
Copper and fiber backbone, patch panels, MPO/MTP cassettes, cable trays and routes, patch frames and labeling.
Video surveillance systems, access control systems, intrusion detection, video analytics and license plate recognition, connection to a remote monitoring center.
Aspirating smoke detection, point detectors, suppression control, gas suppression systems and the associated controls.
SOURCING AND INTEGRATION
What we can help with
- Equipment selection and sizing based on actual IT load
- Vendor-independent sourcing across several manufacturers’ portfolios
- System integration into existing electrical and cooling systems
- Monitoring and control integration with your existing system
- Custom distribution and switchgear cabinet manufacturing
- Agreeing lead times and scheduled delivery
- Project buffer stock to keep construction moving
- Installation, commissioning and commissioning measurements
- Manufacturer warranty and extended support under contract
- SLA-based service with a committed response time

FUNDAMENTALS
How should you choose data center equipment?
Choosing equipment is not a catalog question but a sizing question. Three inputs determine the decision: actual and planned IT load in kilowatts, the availability expected, and the constraints of the existing infrastructure — the incoming supply available, the space, and how much heat can be rejected.
The electrical and cooling sides have to be sized together. Every kilowatt of IT load produces heat that has to be carried away, and the cooling itself consumes electricity. Optimizing the two separately typically produces an oversized UPS and undersized cooling.
Rack density decides what is even in scope. At a few kW per rack, conventional room-level air conditioning is enough; above 15–20 kW per rack, cooling cannot be done economically without in-row or liquid cooling. That decision has to be made before the equipment is bought, not after.

VENDOR INDEPENDENCE
Why we don’t supply from a single manufacturer
One manufacturer's portfolio is rarely the best in every subsystem. Buying the entire mechanical and electrical package from a single brand typically means a compromise at one point at least, and the compromise shows up where it is most expensive to fix.
A vendor-independent approach does not mean a different brand for everything, though. Monitoring and control integration, service support and spare parts supply are all simpler when the elements of one system belong to the same family. The practical rule: consistent within a subsystem, free between subsystems.
The decision is driven by total cost of ownership, not purchase price. A higher-efficiency UPS or a precision cooling unit with better part-load characteristics recovers the price difference through energy cost within a few years.

EXPERIENCE
Common mistakes in equipment procurement
Sizing for nominal output instead of the real profile. Equipment efficiency is decided at part load, and most data centers run at part load for most of the time.
Ignoring lead times. For critical equipment the lead time is often measured in months, and it is what determines the project schedule, not the length of construction.
Redundancy counted in units. Two UPS units are not 2N in themselves if they feed a single distribution board. Redundancy applies to the power path, not to the number of devices.
A skipped compatibility check. How new equipment fits the existing monitoring and control system has to be clarified before ordering.
Buying without warranty and service. Even equipment bought at the best price becomes expensive if there is no service behind it with a committed response time.
Planning a Server Room or Critical Infrastructure Project?
Briefly describe your needs, and one of our engineering colleagues will call you back soon.
or email us directly: info@digitechold.com
Environments we support

Enterprise data centers

Server rooms and edge sites

Manufacturing plant IT infrastructure

AI and high-performance computing (HPC) environments
FAQ
Frequently asked questions about data center equipment
Power, cooling, rack, structured cabling, physical security and fire detection equipment — from the medium-voltage incoming supply to rack-level power distribution, and from precision cooling to aspirating smoke detection. The selection is always project-specific: the equipment list is determined by the result of the sizing, not by a pre-packaged range.
It means we are not committed to a single manufacturer's portfolio, so the decision is driven by technical fit and total cost of ownership. In practice we usually recommend one manufacturer within a subsystem, because of monitoring integration and spare parts supply, while choosing freely between subsystems.
The starting point is actual and planned IT load in kilowatts, plus the redundancy target (N+1 or 2N) and the required autonomy time. We size the cooling for the same load, taking rack density and the available heat rejection into account. The two sides have to be calculated together — optimized separately, the result is typically an oversized UPS and undersized cooling.
It varies a great deal by item and by manufacturer: stock items within days, while larger UPS units, gensets and chillers typically arrive on a lead time of several months. That is exactly why procurement has to start during the design phase of the project — the lead time of the critical item sets the schedule, not the length of construction. For a specific project we state current lead times in the quote.
Alongside the manufacturer's base warranty, extended warranty and SLA-based service can also be contracted, with a committed response time. For critical equipment — UPS, genset, precision cooling — regular maintenance and measurement-based condition assessment also tend to be a condition of the warranty.
Within a subsystem, usually yes; between subsystems, usually no. One manufacturer is rarely the best in every area, but the elements of one system are simpler to integrate and service within a single family. The question is not one brand or several, but where you draw the line.
Beyond the price of the equipment, typically delivery and getting it to site, installation and commissioning, integration with the existing system, commissioning documentation, and the warranty and support level chosen. On larger systems, commissioning measurements and handover documentation are separate line items as well.
Tell us the planned IT load in kilowatts, the availability target, the space and incoming supply available, and whether this is an expansion of an existing system or a new build. If some of that is still open, that's fine — sizing is part of our work. One of our engineers will then go through the details with you.

WHY US?
Why clients choose us
✔ Sizing and sourcing from one source — We don't send a catalog; we send an equipment list calculated from the load and the availability target.
✔ Vendor independence — We assemble the solution from several manufacturers' portfolios, based on technical fit and total cost of ownership.
✔ Integration into the existing system — We clarify how new equipment fits your monitoring and control system before you order.
✔ Predictable delivery — Scheduled delivery and project buffer stock, so construction doesn't stall for want of equipment.
Sizing, sourcing, integration and supportfrom a single source.
Selected references
Enterprise and industrial IT infrastructure projects

Lenovo
Hungary

Citi
Europe-wide

Orlen
Hungary